Installation Manual User guide

Appendix A
Concord Express Installation Instructions 101
yes
1
no
3 minutes
5
09
yes
1
no
siren time
2
10
yes
1
no
sustained
3
11
yes
1
yes
4
momentary
12
yes
1
yes
4
3 minutes
5
13
yes
1
yes
4
siren time
2
14
yes
1
yes
4
sustained
3
15
Notes for Table 17 Response Numbers
Note: The mechanical lifetime of the relay may be exceeded if an output is set up
for a siren tracking response and a pulsing siren (auxiliary or fire) is active for
long time periods. A SnapCard relay output lifetime expectancy is about 350 total
pulsing hours.
1. If an event does not trigger sirens, siren tracking response numbers activate
without turning on the output. If sirens are triggered by another event, the
output pulses to match the siren. If the siren cadence changes (for example
from police to fire), outputs set up for siren tracking change to match the siren
and all pulsing outputs pulse to one common cadence.
2. If an event does not trigger sirens, siren time response times activate outputs
only if sirens are active for another reason.
3. If an alarm event does not necessarily require disarming (no activity, closing
report, etc.), outputs set up for a sustained response time remain activated
until the next arming level change.
4. If an event occurs that activates an output set up for trip delay, the delay and
output activation can be canceled by trigger event restoral.
Note: The trip delay is factory set for 30 seconds and cannot be changed.
5. Activated outputs set up for a 3-minute response time remain active for the
entire 3 minutes. To deactivate the output before the 3-minute time expires,
you must enter program mode or remove panel power. Activated outputs set
up for a momentary or 3-minute response time restart if the same trigger
event occurs again.