Installation Manual User guide

Chapter 1
Concord Express Installation Instructions 5
AC FAILURE set to on
PHONE NUMBER must be programmed
HIGH LEVEL REPORTS set to on.
LOW LEVEL REPORTS set to on
PHONE TEST set to on
AUTO PHONE TEST set to on
PHONE TEST FREQ. set to 1
NEXT PHONE TEST set to 1
LOW CPU BATTERY set to on
COMM FAILURE set to on
RF TX TIMEOUT set to 4 hours
Central Station Reporting
The panel has been tested with the following central station receivers using SIA
and Contact ID reporting formats:
CS-5000 Central Station Receiver
Sur-Gard Central Station Receiver with models SG-DRL2A and SG-CPM2
UL-Canada Listed Systems
This section describes the requirements for ULC (UL Canada) Listed systems.
CSA Certified Accessories
The UL-Canada Basic System is nearly the same as the UL Basic System
described previously, the only difference being that you must use the ITI 60-
679-CN Class II transformer (Basler part number BE 116250-AAA) to power
the panel.
Residential Burglary Alarm System Unit
(CAN/ULC-S309)
Same as “UL Basic System and Household Burglary Alarm System Unit (UL
1023) described previously and siren timeout must be set to 5 minutes or
more.
Residential Fire Warning System Control Unit (CAN/ULC-S545-M89)
Same as “UL Basic System and Household Fire Warning System (UL 985)”
described previously.
Note: For 24-hour backup, external power drain is limited to 90 mA continuous
using a 4.0AH battery.
California State Fire Marshall Listed Systems
Same as Household Fire Warning System (UL 985), plus: