Installation Manual User guide

Appendix C
Concord Express Installation Instructions 109
The panel will recognize the extended version information request from the
downloader and will respond with the extended version response message
used by Enterprise.
An OEM code can be set that will prevent a standard version Toolbox or
Enterprise from communicating with the panel. These panels can only be
downloaded by a version of Enterprise that supports the panels specific OEM
code.
Smoke Verify
Smoke Verify (0900) is now implemented for RF smokes as well as hardwire
smokes. The first trip of a group 26 RF sensor will cause a local fire alarm.
The second trip of any group 26 zone within the siren timeout will cause that
fire alarm to be reported to the central station. RF smoke detectors repeat the
alarm transmission every 60 seconds as long as they are detecting smoke.
This repeated transmission will serve as the second zone trip, causing the
alarm to be reported. If a restoral is sent between alarm transmissions, the
process starts over.
Reports
Zone Restoral (05007) reports are now aborted for a zone alarm that is
canceled in the abort window, even if the zone restores outside the abort
window.
“Report Aborted” now means that an alarm report to the central station was
aborted. In previous releases it meant that an alarm report was aborted and
there were no other events to be reported to the central station at that time.
The event codes reported in CID format for an Auto Force Arm event were
changed from 457 (exit error) to a closing report (401). Some central station
centers dispatch on 457 and didnt want to receive it for a force arm event.
Specifications
Power requirements
Class II, 16.5 VAC, 25 VA, 60 Hz
Rechargeable batteries
12 VDC, 4Ah Lead-Acid (part no. 60-681) OR 12 VDC, 7Ah (part
no. 60-680). The battery will last 24 hours with no AC and
specified standby load
Radio frequency
319.5 MHz
Nominal range
750 feet (305 meters) typical open air
Storage temperature range
30° to 140° F (-34° to 60° C)
Operating temperature range
32° to 120 ° F ( to 4C)
Maximum humidity
90% Relative Humidity (non-condensing)