Installation Manual User guide

Chapter 2
Concord Express Installation Instructions 31
Demo Kit Mode
System Programming
(Default = Off)
This setting determines whether the panel is used for a standard
installation (off) or as a demo kit (on). Turning on this feature and
performing a memory clear changes the following settings:
System Master Code = 1234
User Code 00 = 1001 (standard user code capabilities)
User Code 01 = 1002 (standard user code capabilities, bypass
sensors)
User Code 04 = 1122 (standard user code capabilities, system
tests)
Zone 1 (hardwire) = Group 10, Front Door
Zone 2 (hardwire) = Group 13, Bedroom Window
Zone 3 (hardwire) = Group 17, Living Room PIR
Zone 4 (hardwire) = Group 01, Panic
Zone 5 (wireless) = Group 01, Keychain Touchpad
Zone 6 (wireless) = Group 13, Kitchen Window
COMM FAILURE = off
Entry Delay = 8 seconds
Exit Delay = 8 seconds
Extended Delay = 1 minute
Siren Timeout = 2 minutes
Status Beeps = on (all touchpads)
Central Station Reporting = sensors learned into groups 01 and
03, Duress code use, and phone test (8 + CODE + 2)
To turn Demo Kit Mode
On or Off:
1. With the display
showing DEMO KIT
OFF/ON (current
setting), press 1 (off) or
2 (on). The display
flashes the entered
setting.
2. Press # and the display
shows DEMO KIT
OFF/ON (new setting).
3. Clear panel memory to
enable the demo kit
mode (see next menu).
Clear Memory (System Programming)
System Programming
Clearing memory with the Dealer Code deletes all
existing programming except the Dealer Code.
If the Dealer Code HAS NOT been set, clearing the
memory with the Installer Code deletes all existing
programming.
If the Dealer Code HAS been set, clearing the
memory with the Installer Code deletes all existing
programming except:
Dealer Code
Downloader Code
CS Phone 1
CS Phone 2
To clear Panel Memory:
1. With the system in program mode,
press B until the display shows
CLEAR MEMORY.
2. Press # and the display shows
ENTER CODE TO CLEAR
MEMORY.
3. Enter the 4-digit installer CODE (or
dealer if programmed) + #.
After about one second, the system
restarts and the panel scans the bus to
learn all bus devices. If the system
doesn’t respond as described, repeat
step 3.