Installation Manual User guide

Chapter 2
34 Concord Express Installation Instructions
SIA False Alarm Reduction (0003)
Security-Global (Default = on)
Controls the following settings that are required
by the SIA False Alarm Reduction Standard:
Arming level changes made from wireless
touchpads and keychain touchpads are
sounded (beeps) on exterior siren output
(on) OR are not sounded on exterior siren
output (off).
Note: The siren output must be configured for
“Exterior Siren (016xx) for the arming level
beeps to be annunciated.
The Arming Always Silent feature is
disabled for users if this setting is on OR
can be controlled by users if the setting is
off. Silent Arming on Demand is not
affected.
To turn SIA False Alarm Reduction off or on:
1. With the display showing SIA FALSE ALARM
(current setting), press 1 (off) or 2 (on). The
display flashes the entered setting.
2. Press # and the display shows the new
setting.
The following describes how to program the security settings that appear under
PARTITION 1.
Account Number (0010)
Security-Partition 1 (Default = 00000)
The account number is used as panel (or
customer) identification for the central
monitoring station. The panel sends the
account number every time it reports to the
central station. Account numbers must be 1 to
10 characters long.
Alpha characters A-F can be assigned to the
account number by pressing and holding
buttons 1-6 respectively until the character
appears.
To program an Account Number:
1. With the display showing ACCOUNT NUMBER
nnnnn (current number), enter the desired
account number. The display flashes the
entered setting.
2. Press # and the display shows the new
number.
Quick Arm (0011)
Security-Partition 1 (Default = off)
Quick Arm allows system arming without using
an access code. When this feature is on, the
system arming level can be increased from
Level 1-OFF to LEVEL 2-STAY, from Level 1-
OFF to LEVEL 3-AWAY, or from Level 2-STAY
to LEVEL 3-AWAY without entering an access
code. A valid access code is still required to
decrease the arming level or disarm the
system.
To turn Quick Arm off or on:
1. With the display showing QUICK ARM
OFF/ON (current setting), press 1 (off) or 2
(on). The display flashes the entered
setting.
2. Press # and the display shows the new
setting.