Extended Delay (0312)
Timers-Partition 1 (Default=4 min.)
This setting determines how much time (1-8
minutes) the user has to enter or exit the
premises through a designated extended
delay door without causing an alarm.
Note: For UL Listed systems, Extended
Delay shall not be used.
To set the Extended Delay:
1. With the display showing EXTENDED DELAY
nn MINUTES (current setting), enter the desired
time value (1-8). The display flashes the
entered setting.
2. Press É and the display shows the new setting.
Siren Timeout (0313)
Timers-Partition 1 (Default=4 min.)
This setting determines how long sirens
sound (1-30 minutes) if no one is present
to disarm the system.
Note: For UL Listed systems, Siren
Timeout must be set to 4 minutes or
more.
To set the Siren Timeout:
1. With the display showing SIREN TIMEOUT nn
MINUTES (current setting), enter the desired time
value (1-30). The display flashes the entered
setting.
2. Press # and the display shows the new setting.
Touchpad Options Menu
The TOUCHPAD OPTIONS menu lets you set up touchpad panic and arming
operation. The following describes how to program the touchpad option settings
that appear under PARTITION 1.
Fire Panic (0400)
Touchpad Options-Partition 1 (Default=on)
This setting determines whether
touchpad fire panic buttons are enabled
(on) or disabled (off).
To change the Fire Panic setting:
1. With the display showing FIRE PANIC OFF/ON
(current setting), press 1 (off) or 2 (on). The
display flashes the entered setting.
2. Press # and the display shows the new setting.
Aux. Panic (0401)
Touchpad Options-Partition 1 (Default=on)
This setting determines whether
touchpad auxiliary panic buttons are
enabled (on) or disabled (off).
To change the Auxiliary Panic setting:
1. With the display showing AUXILIARY PANIC OFF/ON
(current setting), press 1 (off) or 2 (on). The
display flashes the entered setting.
2. Press # and the display shows the new setting.