Installation Manual User guide

Chapter 2
Concord Express Installation Instructions 51
Buffer Full Rpt (05006)
Reporting-Global (Default=off)
When this setting is turned on, the panel
sends an “event buffer full” report to the
central monitoring station when the panel
event buffer (memory) is nearly full.
To turn Buffer Full Report off or on:
1. With the display showing BUFFER FULL RPT
OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.
Zone Restorals (05007)
Reporting-Global (Default=off)
When this setting is on, the panel reports
a restoral to the central monitoring station
(or pager) when wireless or hardwire
zones in alarm are reset or restored”
before the alarm is canceled.
Note: As with all UTC panels, hardwire
smoke detectors connected to Concord
or SnapCard hardwire zones do not send
restorals.
To turn Zone Restoral reporting off or on:
1. With the display showing ZONE RESTORALS
OFF/ON (current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press # and the display shows the new setting.
Two Trip Error (05008)
Reporting-Global (Default=off)
This setting works with the Alarm Verifyfeature. If Alarm
Verify is turned on, then the panel waits for a second sensor
trip before sending an alarm (see “Appendix A: Table A3.
Sensor Group Characteristics).
If Two Trip Error is also on and a second sensor trip does
not occur within a 4-minute time period, then the panel
sends an error report to the central monitoring station.
When this feature is turned off, the panel does not send
“Two Trip Error reports.
Note: For UL Listed systems, Two Trip Error must be turned
off.
To turn Two Trip Error off or on:
1. With the display showing TWO
TRIP ERROR OFF/ON (current
setting), press 1 (off) or 2 (on).
The display flashes the entered
setting.
2. Press # and the display shows
the new setting.
TP Panic RPT FMT (05009)
Reporting-Global (Default=off)
This setting determines how the panel formats
touchpad panic alarms reports to the central station.
When this feature is on, touchpad panic alarms report
using the following 3-digit codes:
Auxiliary597, Police598, Fire599
When turned off, touchpad panic alarms report using a
3-digit code from 500 to 503 with the last digit
identifying the touchpad device number.
To turn TP Panic RPT FMT off or on:
1. With the display showing TP
PANIC RPT FMT OFF/ON (current
setting), press 1 (off) or 2 (on). The
display flashes the entered setting.
2. Press # and the display shows the
new setting.