Installation Manual User guide

Chapter 2
60 Concord Express Installation Instructions
Edit Sensors (073)
Sensors (Default=none)
This menu lets you view the assignments for
each learned zone/sensor. For example, the
display shows: S01 P1 G13 NC HW BACK DOOR.
where S01 = zone/sensor number,
P1 = partition 1,
G13 = sensor group 13,
NC = normally closed,
HW = hardwired,
and BACK DOOR is the programmed text
name.
You can also change the zone/sensor group
assignment to eliminate the need to delete and
relearn the zone/sensor.
To Edit Sensors:
1. With the display showing LEARN
SENSORS, press B until the display shows
EDIT SENSORS.
2. Press # and the display shows the lowest
sensor number zone/sensor assignments.
3. Press A or B to scroll through all learned
zone/sensor number assignments.
4. When the desired zone/sensor is displayed
press #. The display shows SENSOR
GROUP nn (current group assignment).
5. Enter the desired group number, then press
#. The display shows the new group
assignment.
Accessory Modules Menu
The ACCESSORY MODULES menu gives you access to the following:
BUS DEVICESthis menu lets you read bus device unit numbers, assign
bus devices to a partition, and set other features associated with a specific
bus device.
Note: Most settings under ACCESSORY MODULESBUS DEVICES have no shortcut
numbers.
SNAPCARDthis menu lets you set the configuration number for each
SnapCard output.
The following describes how to program the settings that appear under
ACCESSORY MODULESBUS DEVICES.