Installation Manual User guide

Chapter 2
64 Concord Express Installation Instructions
Output 1, 2 (09100-output 1) (09110-
output 2)
Onboard Options-Inputs (Defaults: Output
1=00410, Output 2=01710)
This setting lets you assign the selected
output a 5-digit configuration number that
determines which system event activates the
output and the duration or time the output is
activated.
The first three digits represent the trigger
number of an event, such as an alarm, open
sensor, or arming the system.
The last two digits represent how the output
responds, such as momentary, sustained (or
latched), or for a preset time.
Tables A6-A10 in Appendix A identify
system event trigger and response numbers.
To set up onboard Output 1 & 2 partition and
configuration assignments:
1. With the display showing ONBOARD
OPTIONS, press # + B. The display shows
OUTPUT PROGRAMMING.
2. Press # and the display shows OUTPUT 1.
Press # to select OUTPUT 2.
3. After selecting the desired output, press É.
The display shows CONFIGURATION (current
setting).
4. Enter the desired configuration number. The
display flashes the entered number. Press #
and the display shows the new setting.
Exiting Programming Mode
After all installer/dealer programming is completed, use the following procedure
to exit programming mode.
To exit programming mode:
1. Press * until the display shows SYSTEM PROGRAMMING.
2. Press A once and the display shows EXIT PROGRAMMING.
3. Press #. The panel exits program mode and the touchpad displays TIME AND
DATE.
Entering User Programming Mode
The user programming mode lets you program or view the following system
settings:
Time and Date
User Codes
Options
View System Version Information
You can enter user programming from an alphanumeric or fixed display
touchpad, using the system master code.
The system master code default is 1234.