Installation Manual User guide

Chapter 2
66 Concord Express Installation Instructions
User Codes (10nn0--
nn=user 00 thru 15)
User Codes (Default=none)
User Codes perform
basic arming and
disarming functions. The
system allows up to 16
user codes (user
numbers 00-15). User
numbers that show ****
indicate no code is
currently programmed for
that user number.
To program Regular User Codes:
1. With the display showing USER CODES, press # and the display
shows REGULAR USER CODES.
2. Press # and the display shows USER nn (first available user
number).
3. Press A or B to select the desired user number, then press #. The
display shows
USER nn - nnnn.
4. Enter a 4-digit user code and the display flashes USER nn - nnnn
(new code). Press É to accept the new setting.
To delete Regular User Codes:
1. With the display showing USER CODES, press # and the display
shows REGULAR USER CODES.
2. Press # and the display shows USER nn (first available user
number).
3. Press A or B to select the desired user number/user code you
want to delete, then press É. The display shows USER nn - nnnn.
4. Enter a 4-digit code that is the same as the system master code.
With the display flashing the entered code, press # and the
display shows USER nn - **** (no code).
Direct Bypassing
(10nn1--nn=user 00
thru 15)
User Codes (Default=off)
User Codes perform
basic arming and
disarming functions. The
system allows up to 16
user codes (user
numbers 00-15). User
numbers that show ****
indicate no code is
currently programmed for
that user number.
To turn user code Direct Bypassing off or on:
1. With the display showing USER CODES, press # and the display
shows REGULAR USER CODES.
2. Press # and the display shows USER nn (first available user
number).
3. Press A or B to select the desired user number, then press #. The
display shows
USER nn - nnnn.
4. Press B and the display shows DIRECT BYPASSING OFF/ON
(current setting).
5. Press 1 (off) or 2 (on) and the display flashes the entered setting.
Press # to accept the new setting.