Installation Manual User guide

Chapter 3
Concord Express Installation Instructions 75
To Test Outputs:
1. Contact the central monitoring station to inform them that you are testing the
system.
2. Verify that all wiring at the panel and output devices is correct.
3. Activate the appropriate device to trigger each output as programmed.
4. Verify that each output responds according to the programmed configuration
number. For outputs that trigger sirens, verify that the correct alarm sounds
are produced from these sirens. Table 7 on page 76 describes the system
alarm sounds you should hear for each alarm event.
Contact the central monitoring station when you are finished testing.
Caution: Be sure to contact the central monitoring station before activating
outputs that trigger from an alarm condition.
Table 5: Pager system event codes
Code
System event
009
Zone Restoral
111
System Disarmed
118
Trouble Condition Cleared
119
Alarm Canceled
222
System Armed to STAY
333
System Armed to AWAY
555
Phone Test
888
System Trouble Condition
999
System in Alarm
Table 6: Pager codes
Code
System event
000
System event not caused by a zone or user
001 - 0024
Sensor/Zone Numbers 1 - 24
600 - 615
Regular User Codes 0 - 15 used
678
System Master Code used
679
Installer Code used
680
Dealer Code used
697
Quick Arm used
698
Keyswitch Sensor used