Operation Manual
43
Blink
code
Fault Consequence
for the Scooter
Comments
4
Power time
exceeded
Stops driving
• The maximum current was exceeded
over too long a period, probably because
the motor was overloaded or has been
working against an immovable
resistance. Switch the scooter off, wait a
few minutes and then switch on again.
• The electronic system has determined a
motor short-circuit. Check the wiring
harness for short-circuit and check the
motor.
• Contact your Invacare® dealer.
5
Brake failure Stops driving
• Ensure that the disconnection lever is
pressed in.
• There is a defect in the braking coil or in
the cabling. Check the magnetic brake
and cabling for open or short-circuited
circuitry. Contact your Invacare® dealer.
6
No neutral position
when switching
Scooter on.
Stops driving
• Drive lever is not in neutral when the
keyswitch was turned. Put the drive lever
in neutral, turn the power off and then
turn on again.
• It may be necessary to recalibrate the
drive lever. Contact your Invacare®
dealer.