User Manual

20
EN
10. WATER TANK & DRAIN HOSE
There are two ways to remove collected water. Before proceeding ensure that you have
switched o and unplugged the unit.
1. Usage of the water tank
When unit is OFF and the tank of the dehumidier is full, the full indicator will be lit.
Additionally, when the unit is on and the tank is full, indicator will illuminate, and the unit
will automatically stop operating.
• Carefully remove the bucket. Slowly slide the water tank outwards to the accumulated
water does not overow.
• Lift the plastic lid, in order to remove the accumulated water from the tank, once the
water is emptied close the plastic lid once again, and place the tank securely and properly
into the device.
• When the water tank is re-installed the unit will automatically restart.
When you remove the tank, do not touch any parts inside
the unit, as you may damage the device.
Be sure to gently place the tank into the dehumidier.
Do not drink or use the collected water from the device.
Wipe any excess water on, or in, the unit when removing
the tank.
2. Continuous draining
Water automatically can be emptied into a oor drain by
attaching the unit with a water hose.
• Remove the rubber plug located opposite the unit.
Insert the water hose into the drain outlet and make sure
all connections are rmly tightened in order to avoid any
possible leaks.
• The dehumidier - air purier, should be placed on a at
surface in an upright position.
• Lead the water hose towards a suitable drainage facility
and be certain that the water ows naturally. For correct
drainage, make sure the hose stays below the level of the
drain hose outlet.
water drain
hose outlet