User's Manual

16
STEP 6. Balance the Payload
After attaching the scope and accessories, the mount head assembly must be balanced in both
R.A. and DEC axes to ensure minimum stresses on the mount driving mechanism.
CAUTION: The telescope may swing freely when the R.A. or DEC Gear Switch is disengaged.
Always hold on to the mount and/or telescope assembly before releasing the Gear Switches to
prevent it from swinging, which can cause personal injuries and/or equipment damages.
Set the mount at Zero Position. Disengage both RA and DEC gear switches and move the
mount to horizontal position to check balance. Return to Zero Position for balance adjustment. Balance
the DEC axis by moving the scope with accessories back and forth in the mount saddle or within the
scope mounting rings. Balance the assembly in R.A. axis by moving CW along its shaft. Repeat the
process until both DEC and RA axes are balanced.
CAUTION: The balancing process MUST be done with Gear Switch at the total disengaged
position! Otherwise it might damage the worm system.
Figure 22. Balance a mount
Return the mount to Zero Position after balancing and engage gear switches.
STEP 7. Connect Cables
Plug in a 12V DC power supply to the DC12V power socket (size 5.5mm/2.5mm). Connect the
Go2Nova
®
8407+ Hand Controller to the HBX port on the mount base panel.
Figure 23. CEM70G (left) and CEM70/EC (right) mount base panel
For a CEM70G mount, connect USB3.0 port a computer for computer control, iPolar, iGuider
and 3X USB port hub connection.
For a CEM70/CEM70EC mount, Connect USB port to a computer for computer controller.
CEM70 does not have a built-in WIFI.