User's Manual

42
NOTE: If Confirm Position button not active, please click on Clear Center of Camera to erase the
data stored.
Input Rotation Center
You may also manually enter the rotation center, X=480, Y=640, for rough alignment if you are sure the
iPolar camera center is not far away from the mount RA axis.
Step 6. Plate Solving and Polar Alignment
If the iPolar has been calibrated, there will be a bright red cross on the screen, which is the polar scope
camera center/mount RA axis. The alignment software will perform plate solving near the pole star
area. There is no need to see the pole star.
The camera will take the images, enhance the stars and darken the background, remove the noise and
plate solving the area. It will display the pole with a dark RED DOT.
If there are not enough stars, or there are too many stars, you may adjust the exposure time and/or
gains to make sure 5~9 stars can be detected.
Adjust the altitude and azimuth screws to move the RED DOT towards RED CROSS. The image will be
enlarged when they are moving close.
When RED DOT fully covers RED CROSS, the pole alignment is done.
位置 1
位置 2
位置 3
Position 1
Position 2
Camera Center/
RA Axis
Virtual
Pole