Specification Sheet

P:1-800-998-2398
F:1-888-972-4454
www.jdmfg.com
jdmfg@jdmfg.com
6200 Hwy 12
Eau Claire, WI 54701
T
o
t
a
l
S
y
s
t
e
m
S
o
l
u
t
i
o
n
s
Due to our continual effort to provide the best products available and adhere to market conditions; literature, products, prices and availability are subject to change without notice.
Page: 1026
Rev: 02
.
17
J&D Manufacturing’s design allows for more air flow and a consistent air pattern. This maximizes heat distribution and humidity control
by mixing the air, from ceiling to floor – under, over and around your plants.
The Green Breeze HAF fan has precise guard spacing to greatly reduce air restriction when compared to conventional basket fans.
Dirt will not bridge the gaps on the wire grill, to eliminate reduced performance and premature motor failure.
Green Breeze HAF Fan
Patented Open Front Guard
U.S. Patent No. 5,348,447
VRSBR736-U
VRSBR8-U
VRSBR5-U
Gutter
Gutter
Structure air-flow pattern for
gutter connect greenhouse
Green Breeze HAF Fans
Part#
VBG12
VBG20
VBG24
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
Size
12”
20”
24”
HP
1
1
/
10
10
1
/
3
1
/
2
Volts˜
115
115
115
Amps
NP
1.0
3.8
4.8
Hz˘
60
60
60
Phs
1
1
1
Spd^
1/Var
1/Var
1/Var
Thrust
CFM
970
3,650
5,250
Thrust
CFM/
Watt
8.9
11.8
12.1
RPM
1,705
1,691
1,666
kW
.109
.308
.435
Thrust
Eff.
Ratio
7.0
12.2
12.4
Thrust
(lbf)
0.76
3.75
5.41
FPM
525
1,090
1,230
Blade
3-Alm
3-Alm
3-Alm
Test
#
C08032
C16431
C16430
Included
Bracket
VRSBR736-U
VRSBR8-U
VRSBR5-U
Cord
10’
10’
10’
All units are Direct Drive.
NP
Amp information as documented on motor name plate.
˜ These units come pre-wired for 115 Volts (electrician may rewire for 230 Volts).
˘ For 50 Hz compatibility data please contact J&D Manufacturing.
^ Variable speed fans require separate variable speed control to adjust fan speed.
Bold red text is data based on testing performed by an accredited lab using ANSI/AMCA Standard 230-12.