User Manual

j a c l o i n d u s t r i e s | 129 Dermody Street Cranford, NJ 07016
p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133 JACLO.COM
|
PG 11
CREATED 5.2014
|
PG 11
(6) System Check
A. Closehotandcoldcheckstopsonthermostaticvalve.SeeFig.5
B. Setdivertercontroltooffposition.SeeFig.6
 Do not turn on water yet! Diverter of volume control must be off or damage to check stop seals may occur.
C. Closevolumecontrolonbottomthermostaticport(ifapplicable).
D. Turnonhotandcoldmainwatersupply.Checkforleaks,repairifnecessary.
E. Openhotandcoldcheckstops.SeeFig.5
F. Checkforleaks,tightenlocknutsifnecessaryorrepairconnections.
G. Opendivertervalve.Testallpositions.SeeFig.6fordiverteroperation.
H. Openvolumecontrolonbottomofthermostaticvalvebodyifapplicable.
I. Closehotandcoldcheckstopsduringnishedwallfabrication.SeeFig.5
"JACLO INDUSTRIES PROPRIETARY INFORMATION"
THIS DRAWING CONTAIN CONFIDENTIAL PROPRIETARY
INFORMATION AND IDEAS BELONGING TO JACLO INDUSTRIES.
DRAWING ARE BEING DISCLOSED IN CONFIDENCE FOR A LIMITED
PURPOSE AND MUST BE RETURNED UPON REQUEST. IT MAY
NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE
REPRODUCED, COPIED, OR DISCLOSED TO OTHER PARTIES
WITHOUT THE PRIOR WRITTEN CONSENT OF JACLO INDUSTRIES.
INLET
1/2" NPS
3x
5 1/8"
1/2"
2 5/16"
3/8" DIA.
7 7/16"
3 9/16"
3 9/16"
3 9/16"
C PORT
B PORT
A PORT
16 PT.
SPLINE
1 11/16"
Ø1/4"
2x
1 11/16"
1/2" NPS
3x
INLET
C PORT
FULL ON
OFF
C
PORT
B
PORT
NOT
USED
A
PORT
A PORT
FULL ON
"JACLO INDUSTRIES PROPRIETARY INFORMATION"
THIS DRAWING CONTAIN CONFIDENTIAL PROPRIETARY
INFORMATION AND IDEAS BELONGING TO JACLO INDUSTRIES.
DRAWING ARE BEING DISCLOSED IN CONFIDENCE FOR A LIMITED
PURPOSE AND MUST BE RETURNED UPON REQUEST. IT MAY
NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE
REPRODUCED, COPIED, OR DISCLOSED TO OTHER PARTIES
WITHOUT THE PRIOR WRITTEN CONSENT OF JACLO INDUSTRIES.
5 1/8"
1/2"
2 5/16"
3/8" DIA.
3 9/16"
7 7/16"
1/2" NPS
4x
OFF
C PORT
B PORT
A PORT
OFF
OFF
3 9/16"
3 9/16"
C PORT
B PORT
A PORT
INLET
B PORT
FULL ON
C PORT
FULL ON
1/2" NPS
4x
16 PT.
SPLINE
1 11/16"
1 11/16"
Ø1/4"
2x
A PORT
FULL ON
Figure 6
2 WAY
J-TH34-686
J-20686 J-20688
3 WAY
J-TH34-686
THERMOSTATIC
TEMPERATURE CONTROL
THERMOSTATIC
TEMPERATURE CONTROL
DIVERTER
VALVE OPERATION
DIVERTER