User Manual

j a c l o i n d u s t r i e s | 129 Dermody Street Cranford, NJ 07016
p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133 JACLO.COM
|
PG 13
CREATED 5.2014
|
PG 13
(10) Dial Pointer, Trim and Handle Installation
A. Pushthedialpointerontosleevewithpointerontopat12o’clockposition.SeeFig.7.
B. Turnondivertervalvetoallowwatertoow.Measurewatertemperatureandadjustto100°F.
C. Installdialassemblyontospindlealigningthe100°tothedialpointer.SeeFig.7
D. Placeadhesivebackedfoamstriptobacksideoftrimplate.
E. Slidetrimplateoversleeveagainstnishedwall.
F. Installhandletodesiredpositionusingcenterscreworsetscrew,trimsmayvary.
(11) Valve Operation
A. Diverter/Volumecontroloperation.SeeFig.6
i. Twowaydiverterisoffat12o’clockpositionfullon“A”porta9o’clockposition,fullon“C”portat
3o’clockposition.Watervolumeincreasesascontrolmovestowardfullonpositions.Controlmoves
180degreesthroughfulluse.
ii. Threewaydiverterisoffin2,6,10o’clockpositions.“C”portfullonin4o’clockposition.Control
moves360degreesclockwiseorcounterclockwisethroughfulloperation.Watervolumeincreasesas
controlmovestowardfullonpositions.Valvehasdetentsinfullonandstoppositions.
B. Thermostaticvalveoperation.SeeFig.6
i. Temperatureincreasesascontrolismovedcounterclockwise.
ii. Usetemperaturedialasindicator.
Figure 7
DIAL POINTER
DIAL ASSEMBLY