User Manual

j a c l o i n d u s t r i e s | 129 Dermody Street Cranford, NJ 07016
p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133 JACLO.COM
|
PG 8
CREATED 5.2014
(3) PLUMB ROUGH USING APPROPRIATE FITTINGS
Diverter and Thermostatic valve are factory sealed, do not separate!
A.Plumbhotandcoldinletsonthermostaticbody.Part#’s:J-TH34.J-TH12,J-TH34-686,J-TH34-688,
 J-THVC12.SeeFig.3
B. Ifusinglowerportonthermostaticbody,aseparatevolumecontrolisrequired.Ifnot,portmustbeplugged.
SeeFig.3
C. Selectdiverterportstobeused.A,B,Candplumbwithappropriatettings.Note:PortBisnotusedwith
the2-waydiverter,Part#’s:J-TH34-686,J-TH34-688,J-20686andJ-20688.SeeFig.3
Note: Two way diverter can be used as a single outlet and volume control by capping A or C port. Three
way diverter can be used as two way diverter by capping any single port or a volume control by capping
any two ports.
A Port
C Port
B Port
Hot
Inlet
Cold
Inlet
Figure 3
Extra Outlet requires volume
control or plug (not supplied)