WARNING: This product can expose you to chemicals including respirable crystalline silica, which is known to the State of California to cause cancer. For more information go to P65Warnings.ca.gov.
RECOGNITION: I In accordance with ICC-ES Evaluation Report ESR-2290, HardiePlank® lap siding is recognized as a suitable alternate to that specified in the 2006, 2009, 2012 & 2015 International Residential Code for One and Two-Family
Dwellings, and the 2006, 2009, 2012 & 2015 International Building Code. HardiePlank lap siding is also recognized for application in the following: City of Los Angeles Research Report No. 24862, State of Florida Product Approval FL#13192,
Miami-Dade County Florida NOA No. 17-0406.06, U.S. Dept. of HUD Materials Release 1263f, Texas Department of Insurance Product Evaluation EC-23, City of New York MEA 223-93-M, and California DSA PA-019. These documents should
also be consulted for additional information concerning the suitability of this product for specific applications.
DANGER: May cause cancer if dust from product is inhaled. Causes damage to lungs and respiratory system through prolonged or repeated inhalation of dust from product. Refer to the current product Safety Data Sheet before use.
The hazard associated with fiber cement arises from crystalline silica present in the dust generated by activities such as cutting, machining, drilling, routing, sawing, crushing, or otherwise abrading fiber cement, and when cleaning
up, disposing of or moving the dust. When doing any of these activities in a manner that generates dust you must (1) comply with the OSHA standard for silica dust and/or other applicable law, (2) follow James Hardie cutting
instructions to reduce or limit the release of dust; (3) warn others in the area to avoid breathing the dust; (4) when using mechanical saw or high speed cutting tools, work outdoors and use dust collection equipment; and (5) if no
other dust controls are available, wear a dust mask or respirator that meets NIOSH requirements (e.g. N-95 dust mask). During clean-up, use a well maintained vacuum and filter appropriate for capturing fine (respirable) dust or use
wet clean-up methods - never dry sweep.
SILICA WARNING
SQ
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
5 1/4
4
25
50
75
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
6 1/4
5
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
320
340
360
380
400
7 1/4
6
17
33
50
67
83
100
117
133
150
167
183
200
217
233
250
267
283
300
317
333
7 1/2
6 1/4
16
32
48
64
80
96
112
128
144
160
176
192
208
224
240
256
272
288
304
320
8
6 3/4
15
30
44
59
74
89
104
119
133
148
163
178
193
207
222
237
252
267
281
296
8 1/4
7
14
29
43
57
71
86
100
114
129
143
157
171
186
200
214
229
243
257
271
286
9 1/4
8
13
25
38
50
63
75
88
100
113
125
138
150
163
175
188
200
213
225
238
250
9 1/2
8 1/4
13
25
38
50
63
75
88
100
113
125
138
150
163
175
188
200
213
225
238
250
12
10 3/4
9
19
28
37
47
56
65
74
84
93
102
112
121
130
140
149
158
167
177
186
(1 SQ = 100 sq.ft.)
HARDIEPLANK
®
LAP SIDING WIDTH
COVERAGE AREA LESS OPENINGS
Number of 12 ft. planks, does not include waste
COVERAGE CHART/ESTIMATING GUIDE
PAINTING JAMES HARDIE
®
SIDING AND TRIM PRODUCTS WITH COLORPLUS
®
TECHNOLOGY
When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application:
Ensure the surface is clean, dry, and free of any dust, dirt, or mildew
Repriming is normally not necessary
• 100% acrylic topcoats are recommended
DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie
®
Products.
Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature
DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section
COLORPLUS
®
TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE
• Care should be taken when handling and cutting James Hardie
®
ColorPlus
®
products. During installation use a wet soft cloth or soft brush to gently wipe off any
residue or construction dust left on the product, then rinse with a garden hose.
Touch up nicks, scrapes and nail heads using the ColorPlus
®
Technology touch-up applicator. Touch-up should be used sparingly.
If large areas require touch-up, replace the damaged area with new HardiePlank
®
lap siding with ColorPlus
®
Technology.
• Laminate sheet must be removed immediately after installation of each course.
Terminate non-factory cut edges into trim where possible, and caulk. Color matched caulks are available from your ColorPlus
®
product dealer.
Treat all other non-factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer.
Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products.
Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up will not be covered
under the James Hardie ColorPlus Limited Finish Warranty.
This coverage chart is meant as a guide. Actual usage is subject to variables such as building design. James Hardie does not assume responsibility for over or under
ordering of product.
HardiePlank
®
Lap Siding
Product warranties, safety information and additional installation
information are available at jameshardiepros.com
© 2018 James Hardie Building Products, Inc. All rights reserved TM, SM and ®
denote trademarks or registered trademarks of James Hardie Technology Limited.
HS11119 P4/4 12/19