Siding
Panels for sidewall applications are available in 48 in lengths. Pieces needed for one square (100sq.ft.) of product coverage =
approximately 60, based on maximum 5 in exposure.
HARDIESHINGLE
®
STRAIGHT EDGE PANEL COVERAGE
Maximum Exposure of 5 in
Steps 1 - 4
REFER TO STAGGERED EDGE INSTRUCTIONS ON PAGE 3
Figure 29
Steps 5 & 6
second
course
6¼ in HardiePlank
lap siding
trim first panel
to hit center of
furthest stud
1¼ in
starter
strip
14 in
panels
sheathing
water-resistive
barrier
Trim 1/8 in min.
gap for
caulk
DO NOT NAIL THROUGH
THIS AREA
16 in or 24 in
o.c.
3/8 in
5 in
position nails on nail line and secure into framing. Only when application
is to minimum 7/16 in thick APA rated sheathing, position nails on nail
line spaced a maximum of 13 3/4 in o.c. Allow 3/8 in from panel edges.
14 in
panels
1/8 in min.
gap for
caulk
5 in
5 in
first
course
second
course
third
course
PAINTING
CAULKING
For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS,
Class 25 or higher or a Latex Joint Sealant complying with ASTM C834. Caulking/Sealant
must be applied in accordance with the caulking/sealant manufacturer’s written instructions.
Note: some caulking manufacturers do not allow "tooling".
CUT EDGE TREATMENT
Caulk, paint or prime all field cut edges. James Hardie touch-up kits are required to
touch-up ColorPlus products.
PAINTING JAMES HARDIE
®
SIDING AND TRIM PRODUCTS WITH COLORPLUS
®
TECHNOLOGY
When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application:
Ensure the surface is clean, dry, and free of any dust, dirt, or mildew
Repriming is normally not necessary
• 100% acrylic topcoats are recommended
DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie
®
Products.
Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature
DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section
COLORPLUS
®
TECHNOLOGY CAULKING, TOUCH-UP & LAMINATE
• Care should be taken when handling and cutting James Hardie
®
ColorPlus
®
products. During installation use a wet soft cloth or soft brush to gently wipe off any
residue or construction dust left on the product, then rinse with a garden hose.
Touch up nicks, scrapes and nail heads using the ColorPlus
®
Technology touch-up applicator. Touch-up should be used sparingly.
If large areas require touch-up, replace the damaged area with new HardiePlank
®
lap siding with ColorPlus
®
Technology.
• Laminate sheet must be removed immediately after installation of each course.
Terminate non-factory cut edges into trim where possible, and caulk. Color matched caulks are available from your ColorPlus
®
product dealer.
Treat all other non-factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer.
Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products.
Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up will not be covered
under the James Hardie ColorPlus Limited Finish Warranty.
HS1067 P7/8 04/18
HardieShingle
®
Siding
5 IN EXPOSURE HARDIESHINGLE
®
STRAIGHT EDGE PANELS INSTALLATION (For 7 in exposure product please go to page 4)
Steps 1 - 4
DO NOT NAIL THROUGH
THIS AREA
3/8 in
5 in
5 in
5 in
first
course
second
course
third
course
CAULKING
DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie
®
Products. Factory-primed James Hardie products must be painted within 180
days of installation. 100% acrylic topcoats are recommended. Do not paint
when wet. For application rates refer to paint manufacturers specifications.
Back-rolling is recommended if the siding is sprayed.