Instructions / Assembly

INSTALLATION INSTRUCTIONS
for Aluminum Windows without Nailing Fin (JII031)
2
These instructions
specically address:
Installation of a ush •
n window into a
masonry wall.
Installation of a •
nless window into
a masonry or stud
framed wall.
ROUGH OPENINGS
SAFETY & HANDLING
SAFETY
Read and fully understand ALL manufacturers’ instructions before •
beginning.
Do not work alone. Two or more people are required. Use safe lifting •
techniques.
Use caution when handling glass. Broken or cracked glass can cause •
serious injury.
Wear protective gear (e.g. safety glasses, gloves, ear protection, etc.).•
Operate hand/power tools safely and follow manufacturer’s operating •
instructions.
Use caution when working at elevated heights.•
WINDOW & MATERIALS HANDLING
Make sure operable windows are closed and locked prior to •
installation.
Heed material manufacturers’ handling and application instructions.•
Protect adhesive surfaces from dirt, moisture, direct sunlight and •
folding over onto themselves.
Handle in vertical position; do not carry at or drag on oor.•
Do not put stress on joints, corners or frames.•
Store window in dry, well-ventilated area in vertical, leaning position •
to allow air circulation; do not stack horizontally.
Protect from exposure to direct sunlight during storage.•
Install only into vertical walls and when conditions and materials are •
dry.
IF INJURY OCCURS, IMMEDIATELY SEEK MEDICAL ATTENTION!
NEEDED MATERIALS
Note! Follow all material manufacturers' instructions for proper use
and compatibility.
#10 x 2 1/2" corrosion-resistant at head screws. Screws must •
penetrate at least 1" into framing (or as required by local code)
3/16" x 2 1/2" self-tapping concrete screws for masonry applications •
(or as required by local code)
Sealant (Protecto Wrap Protecto Sealant 25XL or equivalent)•
Backer rod•
Non-compressible or water degradable shims•
Polyurethane low expansion foam (Dow Great Stuff•
TM
Window and
Door or equivalent)
For installations into a masonry wall:
Liquid applied ashing (Protecto Wrap LWM 200 or equivalent)•
Self adhesive ashing and spray adhesive/primer if required by local •
code (Protecto Wrap Safseal Systems 5500 or as recommended by
the self-adhesive ashing manufacturer)
For installations into a stud-framed wall:
JELD-WEN drain mat material or equivalent
TOOLS
NEEDED MATERIALS & TOOLS
MASONRY/BLOCK WALL CONSTRUCTION
Windows can be installed into a rough masonry opening with or
without a buck.
Without A Buck
The window will be attached directly to the concrete/masonry.
With Buck
This installation
assumes that a building
professional has already
properly fastened and
sealed a framework of
studs (often called a
buck) to the concrete/
masonry wall.
If using a precast sill,
the buck will be installed only on the head and jambs.
STUD FRAMED WALL CONSTRUCTION
The window will be
mounted inside of the
rough opening.
Tape measure•
Utility knife•
Level (4' minimum •
recommended)
Screwdriver•
Putty knife•
Caulking gun•
Drill with bits•
Masonry
Wall
Buck
Sheathed
Wall
Trimmer
Studs
Header
Sheathing
Sill
King
Stud
Cripple studs