Installation Instructions

TO CONVERTAPPLIANCEFORUSEWITH PROPANEGAS
NATURALGAS-- TO -- PROPANEGAS (LP) CONVERSIONINSTRUCTIONS
I WARNING
Propane Gas conversionis to be performed by a JENN-AIR AUTHORIZED SERVICE
CONTRACTOR(orotherqualifiedagency)inaccordancewiththe manufacturer'sinstructions
and all codesand requirementsofthe authority havingjurisdiction. Failureto follow instructions
could result in serious injury or property damage, The qualified agency performingthis work
assumesresponsibilityfor this conversion.
WARNING I
ELECTRICALPOWERAND GAS MUST BETURNEDOFF PRIORTO CONVERSION.
Manifold-- PropaneGas pressure required........................................................................10"W.C.
IncomingPropane Gas pressure requiredto appliance pressureregulator.................11"- 12"W.C.
PropaneGas conversion OrificeHoods are suppliedwith these models.
MODEL CVG4200, CVG4280 SERIES
BLOWER CAN BE
Propane Gas conversion orifice hoods are supplied with this model. Also available as SERVICE PART NO. 04100251
Propane Gas input specified ........................................................................................................................ 34,000 BTU/hr.
Left rear burner (LR) -- 8,000 BTU/hr. -- #66 odfice -- .033 inches alia. (Zinc Color)
Left front burner (LF) -- 8,000 BTU/hr. -- #66 orifice -- .033 inches din. (Zinc Color)
Right rear burner (RR) -- 9,000 BTU/hr. -- #63 odfice -- .037 inches din. (Blue Color)
Right front burner (RF) -- 9,000 BTU/hr.-- #63 odfice -- .037 inches din. (Blue Color)
MODEL CVG 4100 __
TIE DOWNBOLT
ON EACHI=N APPLIANCEPRESSURE REGULATOR
SLOWERCAN BESWIVELED90_ (_1 WIRING BOX
SWIVELS21= COVER
CONTAINER
Propane Gas conversion orifice hoods are supplied with this model. Also available as SERVICE PART NO. 04100250
.ropane Gas inputspecified ........................................................................................................................ 16,000 BTU/hr,
Left rear burner (LR) -- 8,000 BTU/hr. -- #66 odfice -- .033 inches dia. (Zinc Color)
Left front burner (LF) -- 8,000 BTU/hr. -- #66 orifice-- .033 inches dia. (Zinc Color)
6