Installation Guide

8
To ensure that the grill operates properly, it is recommended
that the island have ventilation on all 4 sides as shown in the
following illustration. The ventilation holes should be as
diagramed to ensure adequate ventilation for your grill and
island.
Proper ventilation is a required based on the above
mentioned specifications for your grill to operate properly.
LP Gas
LP Gas Pressure Regulator/Hose Assembly Location
Measurements shown are for attaching the LP gas pressure
regulator/hose assembly to the enclosure.
Natural Gas Conversion
Natural Gas Pressure Regulator Location
Measurements shown are for attaching the Natural gas pressure
regulator to the enclosure.
Gas Supply Requirements
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149.1 - latest
edition.
IMPORTANT: Grill must be connected to a regulated gas supply.
10 in.
2
(64.5 cm
2
) min.
ventilation both sides
2½" (6.0 cm) max.
1½" (3.0 cm) max.
20 in.
2
(129.0 cm
2
) min.
ventilation both sides
5" (12.7 cm) max.
1¹⁹⁄₃₂" (4.0 cm)
¹³⁄₁₆" (2.0 cm)
10¹⁄₈" (25.7 cm)
16⁷⁄₈" (42.9 cm)
2¹⁵⁄₁₆" (7.5 cm)
1⁹⁄₁₆" (4.0 cm)
18⁷⁄₈" (48.0 cm)
9³⁄₈" (23.8 cm)
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor”
gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 11” (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.