Tech Sheet

11
Manual Diagnostics Mode:
The Manual Diagnostic Mode allows the technician to manually actuate each
relay for testing purposes.
Enter Manual Diagnostic Mode by rotating the Mode Knob clockwise until
the mode id number is displayed by the LEDs.
Once in Manual Diagnostic Mode, rotate the Mode knob or Temperature
knob clockwise, to activate the corresponding relay to each element.
NOTE: For the left cavity use the same operation to enter Manual Diagnostics
Mode.
Each position reached while rotating the knob will turn the elements On/Off
according to the list below:
Knob Position Relay Activated
Temperature Knob - Keep Warm (Right Bake Burners) On/Off
Temperature Knob - Broil Lo (Right Broil Burners) On/Off
Mode Knob - Convect (Right Convect Element) On/Off
Temperature Knob - Clean (Right Motorized Door Lock) On/Off
Button - Oven Light (Right Cavity Light) On/Off
Temperature Knob - Bread Proof (Right Convect Fan) On/Off
Knob Position Relay Activated
Mode Knob - Bake (Right Cooling Fan Lo speed) On/Off
Mode Knob - Broil (Right Cooling Fan Hi Speed) On/Off
NOTES:
For the left cavity use the same table but use the left knob instead.
Mode knob only supports clockwise rotating.
Any new knob movement will turn the current element/burner/fan off.
In order to test the second oven cavity, follow the same test sequence and
procedure.
NOTE: If no action is taken within 5 minutes, the mode times out.