Tech Sheet
11
Manual Diagnostics Mode:
The Manual Diagnostic Mode allows the technician to manually actuate each
relay for testing purposes.
■ Enter Manual Diagnostic Mode by rotating the Mode Knob clockwise until
the mode id number is displayed by the LEDs.
■ Once in Manual Diagnostic Mode, rotate the Mode knob or Temperature
knob clockwise, to activate the corresponding relay to each element.
NOTE: For the left cavity use the same operation to enter Manual Diagnostics
Mode.
Each position reached while rotating the knob will turn the elements On/Off
according to the list below:
Knob Position Relay Activated
Temperature Knob - Keep Warm (Right Bake Burners) On/Off
Temperature Knob - Broil Lo (Right Broil Burners) On/Off
Mode Knob - Convect (Right Convect Element) On/Off
Temperature Knob - Clean (Right Motorized Door Lock) On/Off
Button - Oven Light (Right Cavity Light) On/Off
Temperature Knob - Bread Proof (Right Convect Fan) On/Off
Knob Position Relay Activated
Mode Knob - Bake (Right Cooling Fan Lo speed) On/Off
Mode Knob - Broil (Right Cooling Fan Hi Speed) On/Off
NOTES:
■ For the left cavity use the same table but use the left knob instead.
■ Mode knob only supports clockwise rotating.
■ Any new knob movement will turn the current element/burner/fan off.
In order to test the second oven cavity, follow the same test sequence and
procedure.
NOTE: If no action is taken within 5 minutes, the mode times out.