Ducting Information
(Model CVE407 only)
Jenn-Air's ventilationsystem is designed to capture both cookingfumes andsmoke from
any place on the cooktop surface. If the system does not, these are some ducting
installation situations to check:
6" diameter round or 3 1/4" x 10" rectangular ducting should be used. Note: 5"
diameter round ducting may be used for venting straight out the back of the
cooktop and directly through the wall for 10' or less.
No more than three 90° elbows should be used. Distancebetween elbows should
be at least 18".
Recommended Jenn-Air wall cap should be used. Make sure damper moves
freely when ventilation system is operating.
There should be a minimum clearance of 6"for cooktop installed neara side wall.
If there is not an obvious improper installation, there may be a concealed problem such
as a pinched joint, obstruction in the pipe, etc. Installation is the responsibility of the
installerandquestions should beaddressedfirst bythe installer. The installershould very
carefully check the ducting installation instructions.