- Use and Care Manual Grill-Range Cooktops

Conventional Halogen Radiant
Coil
Conventional Coil
Rated 240 volts........................... AC110B-BlackPomelain
AC110S- Stain(essSteel
AC110W-WhitePorcelain
Halogen
Rated for 240 volts ........................ AH151B-Black
AH151W-Wh{te
Radiant
Rated for240 volts ........................ AR141B-Black
AR141W-White
Jenn-Air'sventilationsystem is designedto capturebothcookingfumes and smokefromany
placeonthegrillsurface. Ifthesystemdoes not,theseare someductinginstallationsituations
to check:
6"diameterroundor3_"xlO"rectangularducUngshouldbeused.Note:5"diameterround
ductingmaybe usedforventingstraightoutofthebackofthe cooktopand directlythrough
the wallfor 10' orless.
No morethanthree90°elbowsshoutdbeused. Distancebetweenelbowsshouldbeatleast
18".
RecommendedJenn-Airwallcap shouldbe used. Makesuredampermovesfreelywhen
ventilationsystemis operating.
There should bea minimumclearanceof 6" for cooktopinstalledneara sidewall.
If there is not an obviousimproperinstallation,there may be a concealedproblemsuchas a
pinchedjoint,obstructionin the pipe,ete. Installationisthe responsibilityof theinstaller and
questionsshouldbe addressedfirstby the installer. The installershouldvery carefullycheck
theductinginstallationinstructions.
15