Installation guide

3
Cabinet Dimensions
Cutout Top View
Electrical Requirements
IMPORTANT: The coffee system must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is
required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this coffee system be provided.
Check that the outlet provides 120-volt power and is correctly
grounded.
A. Coffee system
B. Non-flush receptacle
C. Flush receptacle
D. Back of cabinet
E. Non-flush receptacle located in upper
right or upper left corner
F. Wall behind cabinet
G. Coffee system with runners fully extended
22"
(56 cm)
21⁷⁄₁₆"
(54.5 cm)
min.
17¹³⁄₁₆"
(45 cm) min.
33⁷⁄₁₆"
(85.0 cm)
min.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING