Installation guide

Radiant Cooktop
Models JEC0530 & JEC0536
= JENN-AIR
403 WEST FOURTH STREET, NORTH NEWTON, IA 50208)
IMPORTANT - SAVE FOR THE LOCAL ELECTRICAL INSPECTOR'S USE
IMPORTANT: Installation should be performed only by an authorized Jenn-Air Service Contractor or other qualified
installer. Read safety precautions in the Use & Care Manual before using this appliance.
(Dimensions shown in both inches and centimeters)
JEC0530
FOUR-ELEMENT RADIANT COOKTOPS
DIMENSIONS
inches cm
A 29-1/16 + 1/16 74.0 + 0.2
B 20-3/8 + 1/16 51.9 + 0.2
C 2-1/8 5.4
D 4-1/4 min. clear 10.8
E 29-15/16 76.0
F 21-1/2 54.6
G 3-5/8 7.6
FIGURE 1
NOTE: "D" is clearance needed for unit depth measure down from top of countertop. Typical for all units.
JEC0536
FIVE-ELEMENT RADIANT COOKTOPS
DIMENSIONS
inches cm
A 34-9/16 + 1/16 87.9 + 0.2
B 20-3/8 + 1/16 51.9 + 0.2
C 2-1/8 5.4
D 4-114min. clear 10.8
E 35-5/16 89.7
F 21-1/2 54.6
G 3-5/8 7.6
FIGURE 2
UNITS PROVIDED WITH 1/2" (1.3 cm) I.D. FLEXIBLE CABLE 48" (121.9 cm) LONG WITH 6" (15.2 cm) WIRE LEADS
AT END, FURNISHED AND INSTALLED BY MANUFACTURER (CONNECT TO 240 VOLT ELECTRICAL SERVICE).
INSTRUCTIONS TO INSTALLER:
Side and Back Wall Clearance: Unit may be safely installed as near as 2 1/2 inches (6.35 centimeters) from side
walls and 3/4 inch (1.91 centimeters) from back wall.
Notice To Installer: Leave these instructions with the appliance.
Notice To Consumer: Retain these instructions for future reference.
8101 P645-60
(03-04-00)

Summary of content (2 pages)