Tech Sheet

5
Problem Possible Cause Action
Sparking occurs, and burner does not light. 1. No gas to appliance. 1. Verify proper gas supply.
2. Burner not correctly seated. 2. Check and test.
3. Burner port wet or dirty. 3. Clean and dry. Also clean electrode.
Continual sparking after ignition 1. Electrode wire does not correspond to relevant
reignition module output.
1. Check that the electrode wire is assembled
according to electrode map assembly instruction
located close to reignition module.
2. Burner ports blocked or wet and not allowing
electrode to sense the current.
2. Clean and dry ports and electrode.
3. Spark gap to burner cap not correctly set. 3. Check that the cap is correctly seated on burner.
4. Bad ground connection. 4. Check all ground connections for continuity.
5. Faulty electrode. 5. Verify electrode integrity.
NOTE: The unit may still spark even if the spark lead
is faulty, but the unit will not detect ame.
6. Inversed electrode wires. 6. Check electrode wire colors and correspondent
burner.
7. Faulty reignition control board. 7. Replace and test (only after checking all of the
above).