Installation Instruction

INSTALLATION
24 | INSTALLATION
INSTALLING THE DRAIN PUMP
(CONT.)
12
Attach 1/2" I.D. x 10 ft (3 m) drain tube to
pump discharge tube. Tighten with clamp
received with the drain tube.
NOTE: Do not connect outlet end of drain
tube to a closed pipe system to keep drain
water from backing up into the ice maker.
11
Attach the drain pump power cord to ice
maker unit side wall with clamp and screw
(removed in Step 7) that was used to attach
ice maker power cord.
10
Coil ice maker power cord into a 4"
(10.2 cm) diameter coil. Wrap electrical tape
around the power cord in several places to
keep the cord in a coil. Locate coiled power
cord between the drain pump and side of
enclosure and plug into the receptacle of
the drain pump.
9
Align the 2 screw holes at the rear of the
pump. Use two #8-32 x 3/8" screws,
supplied.
#8-32 x 3/8" pump mounting screws
Receptacle of the
drain pump
Drain pump power cord,
clamp and screw
Drain tube
Clamp