NOTE: Optional blower motor mounting position (opposite side).
The blower motor box assembly can also be moved to the
opposite side (rear) of the vent box.
_s_ _I_,_ _"_,_"_u,s_,,,Bowe_ _I_@oo
2. Lift up the blower box from the bottom mounting channel.
@
B
A
1=
A
A. Panel
B. Blower motor - rear mounting
Loosen the 2 hex/slotted head screws that attach the top
bracket that secures the motor to the vent box enough to
slide the bracket into the "Z" slots. This will move the bracket
away from the top mounting lip of the blower box and allow it
to tilt away from the vent box panel.
A
3.
4=
A. Blower box
B. Bottom mounting channel
Disconnect the wire connector from the blower motor.
o
B
A. Blower motor
B. Wire connector
Remove panel from the opposite side of blower motor.
Loosen the 2 hex/slotted head screws that attach the top
bracket that secures the panel to the vent box enough to
slide the bracket into the "Z" slots. This will move the bracket
away from the top mounting lip of the panel and allow it to tilt
away from the vent box panel.
@
A. Bracket with "Z" slots
B. Hex/slo tted head screws (2)
A
A. Bracket with "Z" slots
B. Hex/slotted head screws (2)