Manual

4,
Connect the 2 white wires together using UL listed wire
connectors.
F
J
C
E
1,
Push and hold the button on the top of the downdraft vent for
a few seconds. The retractable section of the downdraft vent
will rise, and the blower will start. Position the top trim over
the retractable section and snap trim into place.
Trim kits for matching your cooktop color are available from
your dealer.
For information on ordering, see the "Assistance or Service"
section.
B
A. Green or green and yellow ground wire
B. Green ground screw
C. White wires
D. UL listed wire connectors
E. Black wires
F. UL listed or CSA approved conduit connector
G. Downdraft vent wiring
5. Connect the 2 black wires together using UL listed wire
connectors.
6. Replace the terminal box cover and secure with screw.
7. Reconnect power.
E
A. Top trim
B. ON/OFF button
C. Blower control slider
D. End cap
E. Filters
2,
3.
Slide the control slider on the side of vent to check the
operation and speed of the blower.
If the blower does not operate:
Check that filter or filters are pressed in as far as they will
go.
Check that the circuit breaker has not tripped or a
household fuse blown.
Check downdraft vent fuse located under power board.
4. Connect vent system to blower. Vent system must end with a
wall or roof cap. Use clamps to seal all joints.
5. Install cooktop according to manufacturer's instructions.
Check that rear of cooktop overlaps edge of retractable
downdraft vent by 3/8"(9.5 mm). See "Countertop Cutout
Dimensions" in the "Location Requirements" section.
NOTE: To get the most efficient use from your new retractable
downdraft vent, read the "Vent System Use" section.