Manual

Connect Vent System
1. Install vent system.
2. Push duct over the exhaust outlet. Seal all connections with
vent clamps.
Non-Vented (recirculating) Installation
1. Attach the air deflector to the upper horizontal support using
4 mounting screws.
3= Remove the knockout in the terminal box and install a UL
listed or CSA approved 1/2"strain relief.
A B
C
2=
A. Deflector
B. Mounting screws
Measure the length of 8" (20.3 cm) duct needed to connect
the transition to the deflector.
NOTE: Vent should fit up inside the deflector 1" (2.5 cm)
minimum.
3. Install vent between the transition and the deflector.
NOTE: To make vent installation easier, temporarily remove
the deflector from the chimney support bracket and replace
after vent section is in place.
4. Seal all connections with vent clamps.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
4=
A. Knockout
B. Terminalbox
C.Terminalbox cover
Run home power supply cable through strain relief, into
terminal box.
5=
E F
A. Home power supply cable
B. UL fisted or CSA approved strain refief
C. Black wires
D. UL fisted wire connectors
E. White wires
F. Green (or bare) and yellow-green ground wires
Use UL listed wire connectors and connect black wires (C)
together.
1. Disconnect power.
2. Remove terminal box cover.