Operation Manual
16
Fig. 15
B
C
A
100 mm
2. For attaching the Ø 100 mm outside air hose (A) (optional
fi tting - item no. 51012164), refer to the manual (10026187)
supplied with the outside air set. Attach the hose to the
outside air connector (B) using a hose clip (C). Terminate
the insulation approx. 100 mm below the burn chamber.
3. Replace the front cover on the pedestal.
Outside air connection through the base of
the pedestal
Fig. 16
100 mm
B
A
C
4. Remove the cover (A) on the front of the pedestal by lifting
it up and forwards. Place it to one side (see fi g. 14).
5. For attaching the Ø 100 mm outside air hose (A) (optional
fi tting - art. no. 51012164), refer to the manual (10026187)
supplied with the outside air set. Attach the hose to the
outside air connector (B) using a hose clip (C). Terminate
the insulation approx. 100 mm below the burn chamber.
6. Replace the front cover on the pedestal.
4.3 Chimney and fl ue pipe
• The fi replace must only be connected to a chimney and
fl ue pipe approved for solid fuel fi replaces with fl ue gas
temperatures as specifi ed in «2.0 Technical Data».
• The specifi ed distance to fl ammable materials, applies to
this stove.
• The stove must be installed with a CE approved fl ue.
• The distance of the fl ue pipe to combustible materials must
also be observed.
• The cross-section of the chimney must be designed to fi t
the fi replace. Use «2.0 Technical Data» to calculate the
correct chimney cross-section.
• The chimney must be connected in accordance with the
installation instructions of the chimney supplier.
• Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the fi replace and the hole in the chimney. See fi g. 1 for
minimum dimensions.
• With a rear outlet, use a fl ue pipe bend with a sweep hatch
to allow sweeping.
ENGLISH