Installation

SAVE THESE INSTRUCTIONS
JUNO IC20LED (06LM, 09LM, 14LM) & IC22LED (06LM, 09LM, 14LM)
NEW CONSTRUCTION RECESSED HOUSINGS
WARNING: For your safety, read and understand instructions completely before starting installation.
Before wiring to power supply, turn off electricity at the fuse or circuit breaker box.
NOTE: Juno recessed fixtures are designed to meet the latest NEC requirements and are listed in full compliance
with the relevant UL standard(s). Before attempting installation of any recessed lighting fixture, check your local
electrical building code. This code sets the wiring standards and installation requirements for your locality and should
be understood before starting work. Use of non-Juno trims voids Juno warranty.
INSTALLATION INTO
JOIST CONSTRUCTION
Figure 3
Figure 4
Figure 5
Figure 2
Hex Screws
Figure 1
TYPE IC FOR
INSULATED CEILINGS
Juno Type IC fixtures are designed for direct
contact with insulating materials which are
approved for this application (Fig. 1). Fixtures
may also be used in non-insulated ceilings.
Juno Air-Loc LED housings are supplied with pre-
installed gaskets for energy savings and
to comply with energy code air leakage
requirements per ASTM E283.
Step 1. Extend bar hangers to fit between joists.
Bar hanger foot is contoured to easily align
with bottom of joist (Fig. 2). Position fixture by
hammering Real-Nails
®
into joists (Fig. 3).
Note: Bar hanger may be shortened to fit 12”
framing or smaller by breaking at score lines).
Step 2. Slide fixture along bar hangers into
desired location. Use locking screws or slot to
secure (Fig. 4).
Relocating Fixture – Nail can be removed
with hammer claw to allow easy repositioning
of fixture without damaging bar hanger or nail
(Fig. 5).
Step 3. Follow steps 1-4 under Electrical
Connection.
Step 4. When installing in drywall, cut
appropriate sized hole.* After installing drywall,
if necessary, adjust fixture for ceiling thickness
by loosening the three hex screws that attach
the round housing to the plaster frame (Fig. 2).
* Note: Cut 5-5/8” (for 5” housings)
or 6-7/8” (for 6” housings) opening.
1 of 2
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • Visit us at www.acuitybrands.com/juno-recessed
©2017 Acuity Brands Lighting, Inc Rev 3/17 P3758