Note: If
Balance Diff
value is smaller , the voltage difference between batteries will be smaller and
time-consuming will be more when program ends.
If
Balance Set Point
value is smaller , the battery will be closer to the setting cut-off voltage and
time-consuming will be more when program ends.
Balance Over Charge
, the maximum overcharge compensation voltage acts as accelerated
charge, and the larger the value, the more obvious of accelerated charge.
For example: Charge Lipo with Vstd, set
Balance Over charge
to Vboc,the cells internal
resistance
detected is Ri, when the charge current is Ia, the actual CV value of cells is
Va
IF Ri*Ia > Vboc THEN
Va
= Vstd + Vboc
ELSE
Va
= Vstd+Ri*Ia
Please set this parameter after understanding fully, or keep the default value of 0. The value of
Balance Done Delay
is larger; the battery is closer to the setting cut-off voltage when program
ends.
Click " " to enter
LIXX ADVANCED SETUP
, after setting click " " to return to the previous interface.
Note:1.When the battery over-discharges, the charger will charge it with smaller current at the
beginning then turns to normal charging program when the battery voltage reaches the normal
value, otherwise the program will stop running.
2.After charging, the battery may not be completely filled; tick
Keep charging after the done
to
charge the battery with small er current when charging ends.
Click " " to enter
CHARGE SAFETY SETUP
, after setting click " " to return to the previous interface.
Note:
Cut-Temp.
is the maximum safety temperature of the battery and the program will stop running
when the temperature the sensor detected reaches this value, in order to protect the battery
from being damage by the high temperature.
LiXX B attery C harge Advanced Setup
Restore Lowest Voltage :
0.5V/Cell-2.5V/Cell ;
Default : 1V/Cell
Restore Charge Time :
1Min-5Min ; default : 3Min
Restore Charge Current :
0.02A-0.5A ; default : 0. 1 A
LiXX Battery Charge Safety Setup
Cut-Temp
: 20 -80 ; default : 45
Max Capacity:
50%-200%; default : 120 %
Safety Timer:
0Min-9999Min; default : off