DC Battery Charger Manual

X8
Mini Balance Charger/Discharger/DC Power
- 10 -
character, <> to delete the character. Press <> after editing program name to finish. If the program name is
empty, the system will name it automatically.
2. If the Editing program is the built-in program, the program name and battery type etc. parameters cannot be
changed.
After setting the basic parameters of a battery, click " " to enter MEMORY OPTION interface, after setting click
” to return to MEMORY SETUP.
Note: If tick Auto saves before the program runs, the parameters set on the Run program will be saved
automatically, and the Run Program will display “Auto save( shown in the following left picture), otherwise it
will display “Don’t save!” (shown in the following right picture);
Run Program for Charger
After selecting program on MEMORY SELECTION, click to enter Run Program interface (press <> on the initial
interface will enter Run Program from the last running program), as below:
Note: 1. The revised common parameters of built-in program will be saved by default automatically after running,
while the program customized by the user can be set to be saved or not in MEMORY SETUPMEMORY
OPTIONAuto save before the program runs.
2. After setting the Cap. value, when the Current value exceeds the certain value, the system will show a
warning and alarm. The Current value of each battery type is: LiXX battery :> 3C, NiMH/NiCd battery :>
2C, Pb battery :> 0.3C, NiZn battery>2C.
3. Press <> or <> to choose Run Program, the common parameters are in grey, which is inalterable; if
needs to change, the user can press <>, as below:
1: Run Program Selection
2: Common Parameters Setup
3. Auto- save Hint
Auto save before the program runs: if ticking, the modified
parameters will be saved automatically; default: ticking
Run Counter: 0-999; default: 0
Log Interval: 0.5-60Sec; default: 1Sec
Log save to SD card: if ticking, the Log will be saved
to SD card
1
3
2