Error Messages
During the running program, if the system detects an error, it will stop running the program on the channel immediately
and pop up the red dialog box and the buzzer alarms, as below:
Setup of Different Batteries
The following form shows specific range of different batteries:
Nominal
voltage
Charge
voltage
Discharge
voltage
Storage
voltage
Support
Cells
Support
Balance
LiPo
3.7V
3.85V--4.35V
Default: 4.20V
3.00V4.10V
Default: 3.50V
3.70V3.90V
Default: 3.85V
1-8s
Yes
Lilo
3.6V
3.75V4.35V
Default: 4.10V
2.50V4.00V
Default: 3.50V
3.60V3.80V
Default: 3.75V
1-8s
Yes
LiFe
3.3V
3.30V3.80V
Default: 3.60V
2.00V3.50V
Default: 2.50V
3.10V3.40V
Default: 3.30V
1-8s
Yes
LiHV
3.8V
3.90V4.40V
Default: 4.35V
3.00V4.25V
Default: 3.60V
3.75V4.10V
Default: 3.90V
1-8s
Yes
LTO
2.4V
2.50V3.10V
Default: 2.85V
1.50V2.90V
Default: 1.80V
2.40V2.60V
Default: 2.50V
1-8s
Yes
NiZn
1.6V
1.20V2.00V
Default: 1.90V
0.90V1.60V
Default: 1.10V
------
1-8s
Yes
User
------
1.00V4.80V
Default: 1.00V
0.50V4.50V
Default: 1.00V
1.00V4.50V
Default: 1.00V
1-8s
Yes
Pb
2.0V
2.00V2.60V
Default: 2.40V
1.50V2.40V
Default: 1.80V
------
1-15s
No
NiCd/NiMh
1.2V
------
------
------
1-25s
No
LiPo/LiIo/LiFe/LiHV/LTO Battery Charge/Discharge Setup
After adding a program, it will switch to LiPo/LiIo/LiFe/LiHV/LTO battery in Type option on the MEMORY SETUP
interface, and set the number of Cells and Capacity, if there is no setting for the number of Cells, the charger will set
Auto by default, and check Cells automatically via balance head. After editing all parameters for the program, click
" " to save and return to the previous interface.
1: Error number
2: Error message
Press <> to exit the interface, and see all details on
Error Messages.