DC Battery Charger Manual

X8
Mini Balance Charger/Discharger/DC Power
- 16 -
Switch to Balance charge mode on Chg Mode, and click ” behind Chg End Current to enter CHARGE
BALANCE End SETUP interface for setting.
LiPo/LiIo/LiFe/LiHV/LTO Battery Charge Advanced Setup
Click " " to enter LiPo/LiIo/LiFe/LiHV/LTO ADVANCED SETUP, after setting, click" "to return to the
previous interface.
Note: 1. When charging the over-discharged battery, the charger will detect if the cell voltage is larger than the restore
voltage, if larger, it will pre-charge the battery with restore current, if within the setting restore time, the cell
voltage rises to the normal value then it will turn to the charging program; otherwise it will stop running.
2. After charging, the battery may not be completely charged; tick Keep charging after the done to charge the
battery with smaller current when charging ends.
LiPo/LiIo/LiFe/LiHV/LTO Battery Charge Safety Setup
Click " " to enter CHARGE SAFETY SETUP, after setting click" " to return to the previous interface.
Note: Cut-Temp. is the maximum safety temperature of the battery. If the temperature sensor detects the set value,
the program will stop running in order to protect the battery from being damaged by high temperature.
LiPo/LiIo/LiFe/LiHV/LTO Battery Storage Setup
This mode is for storing LiPo/LiIo/LiFe/LiHV/LTO battery that will not to be used for a long time. The charger
determines whether to charge or discharge the battery based on the configured target voltage. If the battery voltage
exceeds the target storage voltage, it will start to discharge, while lower than the target storage voltage, it will start to
charge.
Cut-Temp: 20-80℃; default: 45℃
Max Capacity: 50%-200%; default: 120%
Safety Timer: 1Min-9999Min; default: off
1
2
3
4
1: The charger will stop balance charge if detects the
Balance condition is met, and the End Current
condition is invalid
2: The charger will stop balance charge if detects the End
Current condition is met, and the Balance condition is
invalid
3: The charger will stop balance charge if detects the End
Current condition or the Balance condition is met
4: The charger will stop balance charge if detects the End
Current condition and the Balance condition are met
Restore Lowest Voltage:
0.5V/Cell-2.5V/Cell; Default: 1V/Cell
Restore Charge Time:
1Min-5Min; default: 3Min
Restore Charge Current:
0.02A-0.5A; default: 0.1A