DC Battery Charger Manual

X8
Mini Balance Charger/Discharger/DC Power
- 17 -
Select Program→Storage to enter Storage setup interface.
Note: 1. Accelerated storage: accelerate storage via internal resistance correction. Tick Accelerated storage to
activate accelerated storage.
2. Storage Compensation is the compensation for the battery voltage fallback: for storage charge, the actual
storage voltage=Storage Cell Voltage + Storage Compensation; for storage discharge, the actual storage
voltage=Storage Cell Voltage - Storage Compensation.
LiPo/LiIo/LiFe/LiHV/LTO Battery Discharge Setup
Select Program→Discharge to enter Discharge setup interface.
Note: 1. The charger first discharges with constant current (CC) according to the user setting, then turns to constant
voltage (CV) when it reaches the discharge voltage. In the CV phase the current gradually falls, and the
charger will terminate discharging when the current falls below the percentage of the configured discharge
current.
2. Regenerative mode has two available settings: Off, To input, see more details on Important Notes.
LiPo/LiIo/LiFe/LiHV/LTO Battery Discharge Advanced Setup
Click " " to enter LiPo/LiIo/LiFe/LiHV/LTO DISCHARGE ADVANCED SETUP interface, after setting
click" " to return to the previous interface.
Note: 1. Tick Extra Discharge Enable to activate discharge enable, see more details on Lithium Battery Extra
Discharge Mode.
2. Tick Balance Enable to activate balance discharge; when discharge enters the CV phase, it starts to balance
the cell voltages.
LiPo/LiIo/LiFe/LiHV/LTO Battery Discharge Safety Setup.
Click " " to enter DISCHARGE SAFETY SETUP, after setting click" " to return to the previous interface.
Storage Cell Voltage:3.7V/Cell-3.9V/Cell;
Default: 3.85V/Cell
Storage Compensation: 0V/Cell-0.2V/Cell;
Default: 0.01V/Cell
Discharge Current: 0.05A-30A; default: 2A
Discharge Voltage: 3V/Cell-4.1V/Cell;
Default: 3.5V/Cell
End Current: 1%-100%; default: 50%
Regenerative Mode: OFF (default), To input