DC Battery Charger Manual

X8
Mini Balance Charger/Discharger/DC Power
- 20 -
Note: Regenerative mode has two modes available: OFF, To input. See more details on Important Notes.
NiMH/NiCd Battery Discharge Safety Setup
Click " " to enter DISCHARGE SAFETY SETUP interface, see details about setting on LiPo/LiIo/LiFe Battery
Discharge Safety Setup.
NiMH/NiCd Battery Cycle Setup
Select Program→Cycle to enter Cycle setup interface, see details about setting on LiPo/LiIo/LiFe Battery Cycle
Setup.
Pb Battery Charge/Discharge Setup
After adding program, it will switch to Pb battery in Type option on the MEMORY SETUP interface. Set the number of
Cells and Capacity, after editing all parameters for program, click" "to save and return to the previous interface.
As shown in above picture, the program of Pb battery has the following modes: Charge, Discharge and Cycle.
Pb Battery Charge Setup
Select Program→Charge to enter Charge setup interface.
Note: 1. The charger first charges with constant current (CC) according to the user setting then turns to constant
voltage (CV) when the charging voltage reaches the peak point. In the CV phase the current gradually falls,
and the charger will terminate charging when the current falls below the percentage of the configured charge
current.
Discharge Current: 0.05A-30A; default: 2A
Discharge Voltage: 0.1V-25V; default: 0.8V
End Current: 1%-100%; default: 50%
Regenerative Mode: OFF (default), To input
Chg Current: 0.05A-30A; default: 2A
Chg Mode: Normal (default), Reflex
Chg End Current: 1%-50%; default: 10%
Chg Cell Volt: 2V/Cell-2.6V/Cell; Default: 2.4V/Cell
Cells: 2-15S; default: 6S