DC Battery Charger Manual

X8
Mini Balance Charger/Discharger/DC Power
- 21 -
2. Charge mode has Normal, Reflex two modes available, about the Reflex mode (Reflex) please see Important
Notes.
Pb Battery Charge Advanced Setup
Click " " to enter PB ADVANCED SETUP interface,
Note: When charging the over-discharged battery, the charger will detect if the cell voltage is larger than the restore
voltage, if larger, it will pre-charge the battery with restore current, if within the setting restore time, the cell
voltage rises to the normal value then it will turn to the charging program; otherwise it will stop running.
Pb Battery Charge Safety Setup
Click " " to enter CHARGE SAFETY SETUP interface, see details about setting on LiPo/LiIo/LiFe Battery
Charge Safety Setup.
Pb Battery Discharge Setup
Select Program→Discharge to enter Discharge setup interface, see details about setting on LiPo/LiIo/LiFe Battery
Discharge Setup.
Pb Battery Cycle Setup
Select Program→Cycle to enter Cycle setup interface, see details about setting on LiPo/LiIo/LiFe Battery Cycle
Setup.
NiZn Battery Charge/Discharge Setup
After adding a program, it will switch to NiZn battery in Type option on the MEMORY SETUP interface. Set the
Capacity, the quantity of Cells for NiZn battery cannot be set, and the charger sets Auto by default, after editing all
parameters for the program, click" " to save and return to the previous interface.
As shown in above picture, the program of NiZn has the following modes: Charge, Discharge and Cycle.
Cells: 1-8S; default: Auto
Restore Lowest Voltage: 0.5V/Cell-2.5V/Cell; default: 1V/Cell
Restore Charge Time: 1Min-5Min; default: 3Min
Restore Charge Current: 0.02A-0.5A; default: 0.1A