DC Battery Charger Manual

X8
Mini Balance Charger/Discharger/DC Power
- 22 -
NiZn Battery Charge Setup
Select Program→Charge to enter Charge setup interface.
Note: When the battery cell charging voltage setting exceeds the recommended value (1.9V), the charger will display
a warning and alarm. As long as the user changes the value, the battery type and cell voltage values on the main
interface of charger will display alternately.
NiZn Battery Not Balance Charger Setup
Switch to Not Balance mode on Chg Mode interface, see details about setting on LiPo/LiIo/LiFe Battery Not Balance
Charge Setup.
NiZn Battery Balance Charge Setup
Switch to Slow Balance
Normal Balance
Fast Balance
User Balance on Chg Mode interface, see details about setting
on LiPo/LiIo/LiFe Battery Balance Charge Setup.
NiZn Battery Charge Advanced Setup
Click " " to enter NIZN ADVANCED SETUP interface, see details about setting on LiPo/LiIo/LiFe Battery
Charge Advanced Setup.
NiZn Battery Charge Safety Setup
Click " " to enter CHARGE SAFETY SETUP interface, see details about setting on LiPo/LiIo/LiFe Battery
Charge Safety Setup.
NiZn Battery Discharge Setup
Select Program→Discharge to enter Discharge setup interface
Note: 1.The charger first discharges with constant current (CC) according to the user setting then turns to constant
voltage (CV) when it reaches the discharge voltage. In the CV phase the current gradually falls, and the
charger will terminate discharging when the current falls below the percentage of the configured discharge
current.
2. Regenerative mode has two available settings: OFF, To input, see more details on Important Notes.
Chg Current: 0.05A-30A; default: 1.5A
Chg Mode: Slow Balance
Fast Balance
Normal Balance
User Balance,
Not Balance (default)
Chg End Current: 1%-50%; default: 10%
Chg Cell Volt: 1.2V/Cell-2V/Cell; default: 1.9V/Cell
Discharge Current: 0.05A-30A
default: 1.5A
Discharge Voltage: 0.9V/Cell-1.6V/Cell;default:1.1V/Cell
End Current: 1%-100%; default: 50%
Regenerative Mode: OFF (default),To input