Digital Video Recorder Instructions

11
COM COM
CLOCK
RESET OUT
CLOCK
RESET IN
COM
CLOCK
RESET IN
COM
EXT REC
IN
COM
CLOCK
RESET IN
3 CONNECTIONS (contd.)
3-3 Connecting signal input/output terminals
[CAM SW OUT] camera switching signal
output terminal
To control the camera switching timing from this unit.
[ALARM RESET] alarm signal reset input
terminal
To stop alarm recording when a signal is received during
alarm recording.
[CLOCK RESET IN] clock reset input terminal
To set the clock to the master clock or other devices clock
using a signal from an external device.
[EXT REC IN] external recording control signal
input terminal
Recording can be started, stopped or controlled with an
external signal.
Switch
External
master
clock
External control
device
Starts alarm or sensor recording when a signal is received.
[HDD FULL OUT] HDD full-output terminal
Outputs a signal during recording when the hard disk is full.
* Signal output is possible only when menu switch <HDD
FULL OUT> is set to ON and <REPEAT REC> is not set
to OFF.
[CLOCK RESET OUT] clock reset terminal
Outputs a clock reset signal. It is possible to set the clock of
the digital video recorders following this unit to that of this
unit in second unit.
[ALARM IN] alarm signal input terminal
Last digital video
recorder
External interface specifications example
Use each device rated for using situation.
Control signal
COM
CAM SW
OUT
Frame switchers
camera switching signal
input
COM
Vcc: 5 V-12 V
Vcc
ALARM
RESET
ALARM
IN COM
Frame switcher/alarm sensors
alarm output terminal
COM
HDD FULL
OUT
External
interface
This unit
Second digital
video recorder
GND
Power supply
(Lamp, etc.)
Relay
HDD full lamp
Reference: "3-2 Connecting more than one camera (using an
external switcher)" on page 10.