Operation Manual

Copies of the I/B. Please reproduce them without any
changes except under special instruction from Team
International BELGIUM. The pages must be reproduced
and folded in order to obtain a booklet A5 (+/- 148.5 mm
width x 210 mm height). When folding, make sure you
keep the good numbering when you turn the pages of
the I/B. Don’t change the page numbering. Keep the
language integrity.
4 KA ADH 7 - 101118
Assembly page 4/32
Fax +32 2 359 95 50
CONTROL PANEL
: Full water tank
When this light flashes, it indicates that the water tank is full with water or that the installation
position of the water tank is not correct. In this case, the water in the tank should be emptied or
the water tank should be re-installed to a correct position.
: Power light
When the power of the unit is turned on, this indication light will be on.
ON/OFF & HUMIDITY knob:
Turn this knob clockwise to switch on the appliance and to set the humidity level. MAX position
sets the mode of continuous dehumidifying.
The unit will automatically switch off when the water tank is full or when the power is turned off.
OPERATION
1. Connect the power
Firmly plug into the socket to ensure no hazard of electric shock or fire.
Do not damage the power cord.
When the power is properly connected, the power indication light will be on.
2. Select the dehumidifying level
Turn the ON/OFF & HUMIDITY button to switch on the appliance and to set the dehumidifying
level.
3. Stop operating
During the operational process of the unit, turn the knob to OFF position. The dehumidifier will
stop operating.
Do not try to switch off the unit by pulling out the power plug.
WATER DRAINAGE
A. Emptying the water tank
If the water tank is full (about 3.5 liter), the indication light will be on and the unit will
automatically stop operating.
When the water tank is full, please empty the tank.