User Manual

Single Phase
208-240 Volt
8400JF 3.1JF 5.1JF
Control box
connection
C-85
Hardwire at
shore
C-85
Hardwire at
shore
C-95
Hardwire at
shore
Aerator
connection
plug or
hardwire
into C-85
plug or
hardwire
into C-85
hardwire
into C-95
3 phase 208-
230 Volt
2.3JF 3.3JF 5.3JF 7.3JF
Voltage 208 208 208 208
Amps @208V 7.5 10.3 16.0 20.0
Lock rotor
amps
40 70 100 100
3 phase 460
Volt
2.3HJF 3.3HJF 5.3HJF 7.3HJF
Voltage 460 460 460 460
Amps 3.6 5.1 7.8 10.0
Lock rotor
amps
24 40 49 50
Parts Included
8400JF, 3.1JF, or 5.1JF Aerator
2.3JF, 3.3JF, or 5.3JF Aerator
(Unit with cord or unit with Disconnect) (1)
A1. Cord in separate box (1) (depending on size of cord)
B. Float in separate box (1) (Diagram)
1. 3 Float Sections (1)
2. Top Float Bracket (3)
3. Bottom Float Bracket w/ 50’ rope (3)
4. 9” x 3/8” Black Coated Bolt (6)
5. 3/8” Lock Nut (6)
6. Bottom Screen (1)
7. Top Screen (1)
8. Top Screen Clip (3)
9. 1/4-20 x 3/4” Brass Screw (3)
10. 1/4” Lock Washer (3)
11. 1/4 nut (3)
12. Bottom Screen Clip (3)
13. 3/8-16 x 1” Bolt (3)
14. 3/8 lock washer (3)
15. Mesh screen (1)
16. Cable ties (10)
the other for balance. Note: It is extremely important
to test the GFCI in the control panel upon each instal-
lation/reinstallation of the unit to ensure proper func-
tioning.
USE AND OPERATION
Kasco Aerators are designed and engineered for
continuous duty, such as on sh farms or other aqua-
culture applications, or on-demand use, as needed in a
recreational water feature.
During otation operation, the water is pulled from
360
O
around the unit and from below the unit. The
water is pulled upward and thrust through the otation
collar into the air.
Your Kasco Marine aerator is ready for immediate use
(after installation). Make sure to keep the motor hous-
ing clean from hard water deposits and/or algae. (See
Maintenance Recommendations)
It is extremely important that proper and sufcient
voltage is supplied to the aerator motor. Unit should
be protected by a GFCI. Control panels must be
installed by a qualied electrician. (See Installation
instructions).
Kasco aerators are lightweight, energy efcient, and
easy to install and operate. We strive to produce prod-
ucts that exceed customer expectations. We hope you
enjoy your Kasco aerator.
UNIT STORAGE
When storing units during the offseason, it is impor-
tant to store them upside down if they are going to be
sitting for long periods of time. Units that sit upright
on a shelf for many months, or even years have a
greater likelihood of seals drying out. Storing upside
down will ensure oil is lubricating the seals and pre-
vent drying.
Unit Specs
Single Phase
208-240 Volt
8400JF 3.1JF 5.1JF
Voltage 208-240 208-240 208-240
Amps 10.5 13.4 20
Lock rotor
amps
40 61 97