Owners Manual J Series Fountain 3400JF & 3400HJF 4400JF & 4400HJF C Intertek 3020379 ANSI/UL 778: 2016 Ed.6+R:22Feb2017 CSA C22.2 #108: 2014 Ed.5 Kasco Marine, Inc. 800 Deere Rd. Prescott, WI 54021 PH (715) 262-4488 FAX (715) 262-4487 www.kascomarine.com Rev.
Table of Contents Important Safety. . . . General Instructions. . . . Cord Gauge Chart. . . . Unit Specs. . . . Parts Included. . . . Tools & Supplies Needed. . . . Assembly Instructions. . . . Nozzle Options. . . . Installation Instructions. . . . Maintenance Recommendations. . . . Warranty Policy. . . . Billing. . . . Troubleshooting Tips. . . . 3400J Replacement Parts. . . . 4400J Replacement Parts. . . .
THANKS We at Kasco Marine, Inc. would like to both thank and congratulate you on your purchase of the JF model aerating fountain. We appreciate you choosing Kasco and for your purchase. The JF model Fountain will help improve water quality by adding much needed oxygen and circulation and enhance the aesthetics of the pond or lake with a beautiful fountain pattern. The lighting package (if purchased) will illuminate your fountain for beauty at night.
from hard water deposits and/or algae. (See Maintenance Recommendations.) Cord Gauge Chart It is extremely important that proper and sufficient voltage (120V or 240/208V) is supplied to the Fountain motor. Each 120V Fountain is supplied with a UL and CSA approved C-25 GFI Protected Control Box. The Fountain is to be plugged into the C-25 outlet labeled “UNIT” and the C-25 plugged into a properly grounded receptacle (See C-25 Instructions on page 12).
DWG. NO.
Assembly Instructions 1. Rest the float on the 4 legs of the housing. 3 4 5 Align power cord with notch Align bolt holes with holes on cone. 2. Lock washer goes between bolt and flat washer. Tighten down in 4 places 3. Turn over. Bring bottom screen sections together 10 9 10 11 12 DO NOT SCALE DRAWING C.A.D. GENERATED DRAWING THIS DOCUMENT HAS BEEN ISSUED FOR ENGINEERING INFORMATIONAL PURPOSES ONLY. ANY REVISIONS TO THE CONTENT OF THIS DOCUMENT MUST BE INCORPORATED INTO THE ORIGINAL CAD FILE.
6. Turn upright. Secure power cord to rope hole DWG. NO. With Strain Relief 3400J SERVICE Without Strain Relief OR 431230 DWG. NO. Shipped with Sequoia nozzle preinstalled 7. Choose Nozzle. Push nozzle into cone and twist the 3 tabs to lock into the nozzle plate. DO NOT SCALE DRAWING C.A.D. GENERATED DRAWING THIS DOCUMENT HAS BEEN ISSUED FOR ENGINEERING INFORMATIONAL PURPOSES ONLY. ANY REVISIONS TO THE CONTENT OF THIS DOCUMENT MUST BE INCORPORATED INTO THE ORIGINAL CAD FILE.
Model 3400JF/HJF 4400JF/HJF Nozzle Options Height 7’ 9’ NOTE: Pattern sizes listed are approximate. Variations in voltage caused by regional electrical differences or voltage drop due to long power cords may result Birch Display: The Birch nozzle 431230 (marked B on the part) in reduced pattern sizes. Width 17’ 28’ DWG. NO. To install, place oring around outlet and simply twist the nozzle into the 3 locking tabs. DWG. NO.
Maintenance Recommendations ** Under No Circumstances should anyone enter the water while a fountain is operating. ** ** Please keep the original box for maintenance shipping. ** ALTERNATE INSTALLATION In ponds where the water level fluctuates significantly, you may need to suspend a small weight (12” of 1” galvanize pipe works well) at the mid-point of the rope to take up any slack as the water level drops. The weight should be light enough so the Fountain can rise as the water level rises.
fountains will keep some amount of ice open through the winter. However, when the water is thrust into the air, it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond/ lake. Storage over winter is best in a location that is out of the sun and cool, but above 32OF. When storing units during the offseason, it is important to store them upside down if they are going to be sitting for long periods of time.
the serial number scheme below: claim. Sample Serial # 70 01 VX 2 1725 The first two digits represent the reverse of the last two digits of the year of manufacture. Any expedited shipping method for the return of the unit is at the customer’s expense. Kasco Marine will return units repaired under warranty at our expense via ground freight within the continental United States. Example: 80 = 2008 model year. The third and fourth digits represent the week of the year. (Ex. “01” for 1st week in Jan.) model.
Troubleshooting Tips Below are some helpful troubleshooting tips. If a problem occurs, please double check the assembly and installation instructions as well as the instructions for the proper control panel. More troubleshooting tips can be found at www.kascomarine.com “My Fountain trips the ground fault interrupter in the C-25, C-85, or C-95.” This is the most common symptom of several possible problems. To correctly diagnose the problem, you will need to collect more information.
3400J Replacement Parts 884180 14