Product Manual

TROUBLESHOOTING GUIDE
19
Problem Probable Cause Solution
Unit will not start (when
trigger is depressed)
1. Unit is not turned on.
2. Loose or disconnected
plug.
3. GFCI has tripped.
4. Thermal switch has
tripped.
5. No AC power at the
outlet.
6. Main voltage supply is
too low.
7. Extension cord is too
long or wire size too
small.
8. Defective ON/OFF
switch.
9. Defective GFCI plug.
10. Defective gun.
1. Press ON/OFF switch
into ON position.
2. Reconnect plug.
3. Push reset button on
plug.
4. Allow to cool and
restart unit.
5. Main circuit breaker is
tripped or outlet is faulty.
6. Make sure main supply
voltage is adequate (see
specifications).
7. Remove extension cord
or use proper extension
cord (see instructions).
8. Call Customer Service:
1-800-590-3723.
9. Call Customer Service:
1-800-590-3723.
10. Turn off the unit.
Remove the gun from
the high pressure hose.
Redirect the outlet to
a safe direction and
switch ON the unit.
If the unit starts and
water comes out of
the front, the gun may
need to be replaced.
Call Customer Service:
1-800-590-3723.