Product Manual

TROUBLESHOOTING GUIDE
20
Problem Probable Cause Solution
AC outlet circuit breaker trips
1. Circuit (outlet)
overloaded.
2. Extension cord is too
long or wire size too
small.
3. Nozzle partially blocked
causing excessive
pressure.
1. Make sure circuit is
rated at 15 amps or
greater and unit is
plugged into a dedicated
circuit.
2. Use proper extension
cord (see instructions).
3. Clean nozzle (see
instructions).
Motor stops suddenly
1. Extension cord is too
long or wire size too
small.
2. Thermal safety switch
has tripped due to
overheating and
overwork.
1. Remove extension cord
or use proper extension
cord (See instructions).
2. Make sure main supply
voltage corresponds to
specifications. Allow to
cool and restart unit.
Unit will not stop when
trigger is released
1. Gun/hose assembly is
defective.
1. Remove wand from the
gun and squeeze trigger
to ensure that the water
is coming out of the
front of the gun at a
rate equal to the garden
hose. Call Customer
Service: 1-800-590-
3723.
Unit begins to smoke
1. Overheated, overloaded
or damaged motor.
1. Turn off unit and Call
Customer Service:
1-800-590-3723.
Trigger will not move
1. Gun safety lock in
engaged.
1. Release safety lock (see
instructions).